المواصفات الرئيسية
stop value (the program automatically determines the working mode is cooling / dehumidifying mode)
Setting heating/cooling mode:
Setting mode: Setting (starting temperature): Press and hold the ▲ button to start the temperature flash. Use the ▲ ▼ key to set the starting temperature value.
Setting (temperature off): Press and hold the ▼ button to stop the temperature flashing. Use ▲ ▼ to set the stop temperature value.
Heating use condition: control the water heater, preheat to 65 °C to stop, the temperature drops again to 50 °C and start heating again
Step 1: Heating mode, start temperature < stop temperature
Step 2: Press and hold the ▲ button to start the temperature flash. Use ▲ ▼ to set the starting temperature to 50°C.
Step 3: Press and hold the ▼ button to stop the temperature flashing. Set the stop temperature to 65°C using the ▲ ▼ keys, and setup is complete!
Cooling use condition: Use on the farm, the fan is ventilated to 26°C to stop, raise the temperature to 30°C and start the ventilation again.
Step 1: Cool mode, start temperature > stop temperature
Step 2: Press and hold the button to start the temperature flash. Use ▲ ▼ to set the starting temperature to 30°C.
Step 3: Press and hold the ▼ button to stop the temperature flashing. Use ▲ ▼ to set the stop temperature to 26°C. Setup is done!
Humidify / Dehumidify Mode Settings:
Setting (start humidity): Press and hold the △ key to start flashing the humidity value. Set the humidity value to the △ ▽ key. Adjust [Stop Humidity]: Press and hold the △ key to stop the humidity value flashing, and adjust the humidity so that it stops at the △ ▽ key value.
Humidification example: Fresh supermarket humidification, control humidifier 50%RH start humidification, humidify to 80%RH to stop humidification.
Setup steps:
Step 1: Press and hold the △ button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 50%RH.
Step 2: Long press the ▽ button for 3 seconds to stop the humidity value flashing, set the value to 80%RH, the setting is completed, the button does not work for 5 seconds, and automatically returns to the normal display state.
Dehumidification example: workshop control exhaust dehumidification system, humidity 70%RH starts dehumidifying, humidity 40%RH stops dehumidifying