APC Symmetra Main Intelligence Module

EGP 28,000.00

2 units left

Delivery fees from EGP 20.00 to 6th of October. Save 10 EGP on shipping with prepaid payment

Promotions

Delivery & Returns

Choose your location

Pickup Station

Delivery Fees EGP 20.00
Ready for pickup between 30 April & 01 May when you order within next 9hrs 23mins

Door Delivery

Delivery Fees EGP 35.00
Ready for delivery between 30 April & 01 May when you order within next 9hrs 23mins

Return Policy

Free return within the legal return period from 14 to 30 days, and if they meet the terms & conditions, with the need to report any apparent defect within 48 hours. For more details about return policy.Details

Warranty

1 year

Seller Information

ABC Technology MPDS

60%Seller Score

2 Followers

Follow

Seller Performance

This seller does not have enough history for us to evaluate his performance yet

Product details

Engineered to deliver the highest level of business continuity possible, Symmetra's modular, redundant architecture can scale power and run time as demand increases or when higher levels of availability are required.The SYRIM2 is the redundant intelligent module that works with the APC Symmetra RM series of power Arrays. This SYRIM2 module is refurbished and comes with a one year replacement warranty. Remove your old module and replace it with this new one, installation is plug and play.

1) On most Symmetra systems, the Powerview LCD display connects to one of the intelligence modules via a cat5 UTP patch cable. This cable should be disconnected from the intelligence module to which the display connects. If the UPS being serviced is a Symmetra Power Array (Masterframe or Miniframe) this will not be necessary as the Powerview display does not directly connect to either intelligence module.

2) If, for some reason, there is only one intelligence module installed, the UPS must be placed into the maintenance bypass mode of operation prior to removing this single intelligence module. This should be done by closing the breaker marked maintenance bypass. Depending on which Symmetra UPS is being serviced, the location of this breaker will vary. If there are two intelligence modules, it is not necessary to place the UPS in bypass.
* when engaging the Maintenance Bypass breaker on the Symmetra LX, it should be firmly and swiftly pushed to the right to ensure that the load does not experience any interruption in power.

3) Locate the failed intelligence module and remove it. If two intelligence modules are installed, the remaining intelligence module will assume control of the UPS if it has not already. The failed intelligence module can be identified by a solid red LED illuminated on the intelligence module's LED array. It can also be identified via the PowerView display.

4) Insert the replacement intelligence module and allow it several seconds to boot.

Specifications

Key Features

  • 1) On most Symmetra systems, the Powerview LCD display connects to one of the intelligence modules via a category 5 unshielded twisted pair patch cable. This cable should be disconnected from the intelligence module to which it connects in order to ease the process of installation. If the UPS is a Symmetra Power Array (Masterframe or Miniframe) this will not be necessary as the Powerview display does not directly connect to either intelligence module.
  • 2) Remove the intelligence module that is not in control.

          Symmetra LX will indicate which intelligence module is in control by illuminating an additional green LED on the              far left of the LED array. Symmetra Power Array and Symmetra RM indicate which module is in control using the              redundant intelligence module's orange LED (second LED from the left on the LED array). If this LED is                            illuminated, the redundant intelligence module is in control. If this LED is not illuminated, the main intelligence                  module is in control.

  • 3) Insert the replacement intelligence module in the now empty bay. Allow this module several seconds to boot up and confirm that the module is operating properly by the LEDs illuminated on the intelligence module. The green LED to the far right of the module's LED array should be solid. If the red fault LED on the intelligence module illuminates and stays lit, there is a fault. Please contact APC support.
  • 4) Remove the remaining intelligence module and insert the second replacement module. Allow this module to boot up and confirm that the module is booted by the LEDs present on the module. The green LED to the far right of the module's LED array should be solid. If the red fault LED on the intelligence module illuminates and stays lit, there is a fault. Please contact APC support.
  • 5) Ensure that the main intelligence module has assumed control of the UPS.

           ]Symmetra LX will indicate which intelligence module is in control by illuminating an 

Specifications

  • SKU: AP150EA114B83NAFAMZ
  • Model: SYMIM2
  • Production Country: USA
  • Size (L x W x H cm): 45.9 x 19.7 x 54.4
  • Color: Silver
  • Main Material: metal

Verified Customer Feedback

This product has no ratings yet.

APC Symmetra Main Intelligence Module

APC Symmetra Main Intelligence Module